AirLife

Active humidification

Heated humidifiers

MR290 Chamber

MR850 Heater

Fisher & Paykel Healthcare single-use humidification chambers

Fisher & Paykel Healthcare heated humidifiers We offer an advanced line of heated humidifiers. Choose from a wide variety of models. Humidifier MR850 is designed to provide optimal levels of humidification for all patients with a simple user interface and one-button control. For use with intubated or non- intubated patients, it includes intelligent alarms, a condensate control feature and water-out alarm. Because it has simple controls and alarm features, Humidifier HC500 is ideal for home-care applications. It is a dual servo microprocessor-controlled device that may be used with or without heated wire circuits. For oxygen therapy, headbox applications and CPAP, Nonservo Humidifier MR410 is a simple and reliable choice. Humidifiers operate on 115V. UL listed.

Fisher & Paykel Healthcare single-use humidification chambers provide quality, high-performance features. Chamber MR225 for infants provides low compressible volume. Chamber MR250 for adults offers high-flow performance. Chamber MR290 is an auto-fill design that provides low compliance and constant compressible volume. This, combined with its excellent performance over a wide range of flows, means that it can be used for applications from neonatal to adult.

Cat. no. MR225 MR250

Description

Qty.

Infant/pediatric chamber, low compressible volume

50/cs 40/cs

Cat. no. MR850 HC500 MR410

For use in

Qty. 1/cs 1/cs 1/cs

Adult chamber, high flow

Critical care (with advanced features)

All-purpose chamber, continuous water feed system, constant compressible volume

MR290

40/cs

Homecare

Noncritical applications (nonservo) , CPAP and oxygen therapy

MR290HFV

Continuous water feed system, high frequency ventilation 40/cs

Homecare humidification chamber, adult, for use with Humidifier HC500

HC325S

1/cs

Fisher & Paykel Healthcare humidifier heated wire adapters Our heated wire adapters are for use with MR800-, HC500- and MR700-series heaters.

Fisher & Paykel Healthcare humidifier airway temperature probes

These right angle airway probes are designed for use with a variety of circuit sizes for MR800-, MR700- and HC500-series humidifiers. The reflective shield protects airway temperature probes from radiant heat to improve humidifier performance with infant radiant warmers. Right angle temperature/flow probes for MR800-Series humidifiers 900MR869 60" (1.5 mm) circuits 1/cs Right angle temperature probes for MR700- and HC500-Series humidifiers 900MR560 52" (1.3 mm) circuits 1/cs 900MR569 60" (1.5 mm) circuits 1/cs 900MR561 72" (1.8 mm) circuits 1/cs 900MR571 92" (2.5 mm) circuits 1/cs Reflective shield 900MR208 Temperature probe 20/cs 1/cs 900MR861 72" (1.8 mm) circuits Cat. no. For use with Qty.

Cat. no.

Description

Qty.

For use with MR850 humidifiers 900MR805

For dual-heated breathing circuits For inspiratory heated breathing circuits

1/cs 1/cs

900MR806

For use with MR700, MR720 and MR730 humidifiers 0060-23 For use with MR700- and HC500-Series humidifiers 900MR555

Series dual adapter (equivalent to 900MR555)

1/cs

For serial wired dual-heated isothermal breathing circuits For inspiratory heated isothermal breathing circuits; single adapter For dual-heated breathing circuits, Fisher & Paykel Healthcare RT-series circuits For inspiratory-heated breathing circuits, Fisher & Paykel Healthcare RT-series circuits

1/cs

900MR559

1/cs

900MR900

1/cs

900MR901

1/cs