Workholding Solutions Master Catalog
BALL LOCK ® MOUNTING SYSTEM
WORKHOLDING SOLUTIONS GROUP
METR IC DIMENS IONS - METR IC F IXTURE /SUBPLATES
A QUICK CHANGE FIXTURING » BALL LOCK ® MOUNTING SYSTEM METRIC Pallet Size (mm) 400 500 630 400 500 630 B 16mm Bored holes for sine fixture keys (2) places 16mm Bored holes for sine fixture keys (2) places Receiver Bushings Primary Liners
Subplates for Tooling Columns and Fixture Plates Standard Steel Subplates for Tooling Columns Subplate Mounting holes can be provided per customer specification. Supplied with Ball Lock ® Receiver Bushings installed.
Ball Lock ® Pattern
Receiver Size (mm)
Thickness of Subplate (mm) ±0.13
Part Number 59102 59103 59103-C
Pallet Size (mm)
For Tooling Columns
Wt. (Kgs)
A (mm)
B (mm)
400 500 500
350 425
350 425
20 25
28.57 31.75 31.75
31 59 59
69151, 69051 69161, 69061 69151, 69051 69161, 69061 69171, 69071
350/425 350/425 20/25
— —
Dual 525
Dual 525
Dual
— —
630
35
34.92
124
59104
Fixture Plates for Standard Tooling Columns and T-Columns Supplied with 2 primary Ball Lock ® Liner Bushings installed.
Part Number
Ball Lock ® Pattern
Fixture Plate Size (mm)
Fixture Plate Thickness (mm) ±0.13
Liner Size (mm)
For Tooling Columns Type
H (mm)
G (mm)
Aluminum (kg)
Steel
(kg)
7
19 36 50 25 53 63
4-S 250x500 20 4-S 300x625 25 4-S 400x650 25 T 400x400 20 T 500x550 25 T 625x650 25
150 450 20 175 550 25 275 575 25 350 350 20 425 475 25 550 575 25
58741 58742 58743 58717 58745 58746
58841 58842 58843 58817 58845 58846
69051 69061 69071 69151 69161 69171
13 18
8
19 27
Fixture Plates for Tooling Column Subplates Supplied with 2 primary Ball Lock ® Liner Bushings installed.
Ball Lock ® Pattern
Part Number
Plate Dim.
16mm Bored holes for sine fixture keys (2) places
Pallet Size (mm)
Fixture Plate Thickness ±0.13 (mm)
Liner Size (mm)
E ( mm )
F ( mm )
For Subplate
I (mm)
J (mm)
I
F
Aluminum (kg) Steel (kg)
400 500 630
8
25
400 400 500 500 630 630
20 25 25
350 350 20 425 425 25 525 525 35
58717 58727 58732
58817
59102 59103 59104
17 27
58827 48 58832 76
Primary Liners
J E
Aluminumand Steel Expansion (per cm)
0.0015
0.00125
0.001
0.00075
( mm )
0.0005
0.00025
0
Difference between Aluminum and Steel 0
5.4
8.4
11.2
14
16.8
2.8
Change in Degrees C
NOTE: Aluminum and steel expand at different rates. Please take this information into consideration when creating your own Ball Lock ® fixture and subplates.